Abstract
Rupture of the colon caused by high pressure compressed air is a rare, unique and traumatic intra-abdominal injury. As the use of compressed air in industrial work has increased, so has the risk of associated pneumatic injuries from its improper use. Recently we experienced a case of pneumatic rupture of the sigmoid colon accompanied by tension pneumoperitoneum, which caused respiratory distress. The patient's respiration was very rapid with the rate of 44 breaths per minute. On arterial blood gas analysis, pH was 7.40, pO2 68 mmHg, pCO2 44 mmHg, and SaO2 90%. Chest X-ray film showed marked pneumoperitoneum and an elevated diaphragm. The respiratory distress was severe and required immediate relief by emergency decompression peritoneocentesis before surgical intervention consisting of the serosal tear repair, colonic rupture colostomy and abdominal cavity irrigation. A follow up operation 2 months later for colostomy repair completed the patient's recovery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.