Abstract

To avoid damaging the motor and its surrounding equipment, detecting Inter-Turn Short Circuit (ITSC) faults in Permanent Magnet Synchronous Motors (PMSMs) applied in electric vehicles is a crucial task. In this paper, the detection of ITSC faults in stator winding for PMSMs is carried out by means of the Extended KALMAN Filter (EKF) algorithm combined with the Fuzzy Logic Estimator (FLE). To estimate the motor parameters, including the rotor position and speed, the EKF algorithm uses the measured stator currents and voltages beside the stator resistance, which is calculated in advance using fuzzy logic and fed to the EKF. The change behaviors of the estimated parameters were then used to detect short circuit faults in the PMSM. Using Matlab/Simulink, the proposed FL-EKF algorithm was implemented and tested on a faulty PMSM controlled by Field Oriented Control (FOC). The observation of a perfect estimation of the stator resistance through the simulation helps to precisely detect the failure, and that demonstrates the sensitivity and robustness of the proposed approach.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.