Abstract

Information on plume rise is important in determining the resulting concentrations of a pollutant on the ground. Practical use of plume rise values may be made in connection with stack design, the use of urban air pollution models, and in evaluating the hazards to a population complex. This paper presents a new equationless technique for estimating plume rise as well as a comparison of seventeen commonly used plume rise formulas. Data from 10 sets of experiments, involving 615 observations and 26 different stacks, were used to study the relation between plume rise and related meteorological and stack parameters. An independent data set was used to test the derived methods for determining plume rise. These data were obtained by Bringfelt of Sweden and contained measurements from stacks smaller than that at the Argonne National Laboratory to those approaching the TVA stacks. A significant improvement in the prediction of plume rise from meteorological and stack parameters resulted from the use of a new tech...