Abstract

Existing sub-/super-synchronous (SSO) suppression methods for the direct-drive permanent magnet synchronous generators (D-PMSG) integrated power systems are mainly achieved by external devices or sub-synchronous resonance damping controller (SSRDC) at the converters, facing challenges of considerable control costs, complex parameters tuning, or inadaptability to various operating conditions. To address these problems, this paper proposes an adaptive SSRDC based on the phase-locked loop (PLL) for D-PMSG integrated power systems. Firstly, the PLL parameter is found critical to SSO suppression by a comprehensive sensitivity analysis on the dominant poles of the impedance closed-loop transfer function. Motivated by this finding, this paper then designs a PLL-based SSRDC, which features a simple structure, easy parameter tuning, and flexible adaptability to various operating modes. The simplicity in structure is guaranteed by the avoidance of phase compensation. Benefiting from the simple structure, only one key parameter needs to be tuned. Moreover, two principles of parameter tuning are proposed to enhance the efficiency, robustness, and adaptability of the proposed SSRDC. The controller-hardware-in-the-loop (CHIL) tests verify the validity of the proposed SSRDC under various operating conditions. Finally, some concerns about this method such as frequency estimation, computational efficiency and potential impacts on PLL are thoroughly analyzed and clarified.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call