Abstract

Platinum (Pt) dissolution has been elucidated by measuring a mass loss of Pt black-deposited Au quartz resonators in 0.1 mol dm-3 HClO4 containing NaNO2. A continuous weight loss of ca. 50 ng cm-2 cycle-1 was detected at [NaNO2] = 0.01 mol dm-3 under the potential cycling between 0.6 and 1.4 V vs. RHE. The magnitude of Pt dissolution depends on the concentration of NaNO2 and the range of potential cycling. The average mass loss decreases to 5~10 ng cm-2 cycle-1 at [NaNO2] = 1 mmol dm-3. The Pt dissolution occurs when the higher potential limit is more than 1.0 V vs. RHE and the lower potential limit is less than 0.9 V vs. RHE, suggesting that the reduction of Pt oxide in the presence of NaNO2 in the bulk solution contributes to the dissolution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.