Abstract

Septic reactions from platelet transfusions are one of the leading causes of transfusion-associated mortality. The FDA guidance for platelet bacterial risk control includes bacterial culture using both aerobic and anaerobic bottles. Several studies have reported false positive rates (FPR) of culture, but these data have not been summarized or influencing factors analyzed. A systematic review and meta-analysis was performed according to published guidelines to assess the false positive rate and influencing factors. Eighteen studies were included for analysis. The combined aerobic/anaerobic FPR was 2.4 events per thousand (EPT) with a prediction interval of 0.5 to 5.7, while the aerobic FPR rate was 1.0 EPT (prediction interval: 0.2-2.2) and the anaerobic rate was 1.8 EPT. Estimates were based on a total of almost 5 million units tested. The rate of false positives due to instrument error was between 0.5-1.7 EPT, while it was between 0.3-1.0 EPT for sampling contamination based on whether only aerobic, anaerobic, or aerobic/anaerobic cultures were performed. The FPR is approximately 2 to 5 times higher than the literature reported true positive rate of 0.5 EPT.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.