Abstract

BackgroundWhile open wedge high tibial osteotomy (owHTO) is an established standard procedure to treat medial osteoarthritis of the knee in combination with varus deformity, it bears the risk of postoperative hardware failures and lateral cortical hinge fractures. This in turn can lead to an accelerated osteoarthritis, non-union, or a loss of correction accuracy. The purpose of the study was to evaluate the radiologic outcomes of owHTO with a carbon fiber reinforced poly-ether-ether-ketone (CF-PEEK) plate fixation in patients with medial osteoarthritis and varus deformity.MethodsThree hundred twenty-four consecutive patients (346 knees) who were treated with owHTO using the PEEKPower HTO plate were included in this retrospective study; 89.9% of the patients were overweight or obese. Patients were followed by conventional radiographs over a 12-month period. Typical plate-related results such as the time and quality of gap healing as well as the correction accuracy were analyzed. Furthermore, the number of lateral cortex fractures was determined.ResultsBony consolidation was observed after a mean gap healing time of 4.0 ± 1.7 months independent on the patients’ weight (p = 0.2302). With increasing gap sizes, bony healing was significantly prolonged (p < 0.001). Additionally, patients with greater gap sizes had a significantly increased risk for a lateral cortex fracture (p = 0.0041). However, none of the patients had a non-union 1 year postoperative. A hinge fracture occurred in 30% of patients. Hinge fractures with Takeuchi grades I and II increased the gap healing time compared to no fracture (p = 0.0069 and p = 0.0002, respectively), but only 1.2% of patients with hinge fracture had a clinical relevant loss of correction ≥ 3 mm. No implant failures were found.ConclusionsOpen wedge HTO using the PEEKPower HTO plate for patients with medial osteoarthritis of the knee in combination with tibial varus deformity leads to excellent bony consolidation also in cases with a hinge fracture, a gap size > 12 mm as well as for severely obese patients.

Highlights

  • While open wedge high tibial osteotomy is an established standard procedure to treat medial osteoarthritis of the knee in combination with varus deformity, it bears the risk of postoperative hardware failures and lateral cortical hinge fractures

  • While open wedge high tibial osteotomy (owHTO) is a standard procedure, it bears the risk of postoperative hardware failures and lateral cortical hinge fractures [4,5,6]

  • A lateral hinge fracture is a typical complication of owHTO

Read more

Summary

Introduction

While open wedge high tibial osteotomy (owHTO) is an established standard procedure to treat medial osteoarthritis of the knee in combination with varus deformity, it bears the risk of postoperative hardware failures and lateral cortical hinge fractures. This in turn can lead to an accelerated osteoarthritis, non-union, or a loss of correction accuracy. Open wedge high tibial osteotomy (owHTO) is an established surgical procedure to treat patients with medial osteoarthritis of the knee in combination with varus deformity [1,2,3]. The authors suggested increasing the IFM of the implants in order to avoid incomplete bone healing

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call