Abstract

The oxygen recombination (reduction) rate on plastic-bonded cadmium electrodes in sealed NiCd systems can be increased by using metal screens applied to the gas side of the plastic-bonded cadmium electrode. The metal screen applied should have an optimum geometry (mesh size, wire diameter) to provide optimum conditions for the existence of a uniform electrolyte film covering the total screen surface. The oxygen recombination rate in such a case is high enough to enable this type of cadmium electrode to be used in practical sealed cells. No major differences between steel and nickel screens were noticed, but with a silver plated screen a substantially enhanced oxygen recombination rate was observed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.