The plastic collapse and LBB behavior of statically indeterminate piping system were investigated in this study, compared with those of the statically determinate piping system. Special attention was paid to evaluate the crack opening displacement after a crack penetrated wall thickness. The main results obtained were as follows: 1. The reduction of ultimate strength caused by a crack was relatively small in the statically indeterminate piping system. The main reason is thought to be that a sufficient redistribution of the bending moment occurs in this system. 2. A method to evaluate the crack opening displacement after crack penetration in a pipe with a non-penetrating crack was proposed. From this method, it was known that the crack opening displacement could be evaluated by using the incremental plastic rotation angle. 3. The acceptable defect size considering the deformation of a pipe was estimated by comparing the plastic moment at the defective part and the gross yielding moment at the non-defective part.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.