Abstract

A process that combines polymer nanoreplica molding with horizontal dipping was used to fabricate large area ( <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">$\sim 3\times 5~{\rm inch}^{2}$</tex> </formula> ) distributed feedback laser biosensors (DFBLB) on flexible plastic substrates, which were subsequently incorporated into standard format 96-well microplates. A room temperature nanoreplica molding process was used to create subwavelength periodic grating structures, while a horizontal dipping process was used to apply a <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex Notation="TeX">$\sim {300}~{\rm nm}$</tex></formula> , dye-doped polymer film. In this work, the DFBLB emission wavelength, used to characterize the device uniformity, demonstrated a coefficient of variation (CV) of 0.41% over the fabricated device area, representing a thickness standard deviation of only <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">$\sim {35}~{\rm nm}$</tex></formula> for the horizontal dipping process. The fabricated sensors were further characterized for sensitivity uniformity by measuring the bulk refractive index of the media exposed to the sensor surface and by measuring adsorption of biomolecular layers. An assay for detection of the cytokine Tumor Necrosis Factor-alpha (TNF- <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">$\alpha$</tex> </formula> ) was used to demonstrate the operation of the sensor in the context of label-free detection of a disease biomarker. The demonstrated capability represents an important step towards roll-to-roll manufacturability for this biosensor that simultaneously incorporates high sensitivity with excellent wavelength shift resolution, and adaptability to the microplate format that is ubiquitous in pharmaceutical research.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.