Abstract
The characteristics of segmented plasmatron are presented. The arc is sustained in argon plasma and in plasma stream, argon, nitrogen and carbon-dioxide are introduced. The numerical simulation of argon electric arc and plasma stream is carried out and the temperatures and densities of electron and heavy particles are presented. Experimental and theoretical investigations determine and explain the influence of natural gas and flow rate injected into plasma stream on working plasmatron conditions. The anode voltage drop analysis shows that in plasmatron working at a current between 40 and 340 A, gas flow rate between 0.4 and 2 g/s and pressure from 5 to 100 kPa, this drop changes from negative to positive, influencing arc voltage value. The gas injection into plasma stream results in anode spot dynamic. Electric breakdowns accompanied by high voltage fluctuations are observed when argon or nitrogen is introduced while carbon dioxide eliminates this type of breakdown reducing the voltage fluctuations and ablation of electrodes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Dielectrics and Electrical Insulation
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.