Abstract

Deuterium-deuterium and deuterium-tritium reaction rates may be compared to determine plasma temperatures in the 10- to 200-eV range. Distinguishing neutrons from these two reactions is difficult when yields are low or unpredictable. Time-of-flight (TOF) methods fail if the source is extended in time. These neutrons may be distinguished because inelastic scattering of more energetic neutrons by carbon produces a 4.44-MeV gamma ray and because hydrogenous material preferentially attenuates lower-energy neutrons. We describe a detector system that can discriminate between lower- and higher-energy neutrons for fluences as low as O(102) neutrons per sterad even when TOF methods fail, define a figure of merit, and calculate its performance over a broad range of parameters.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.