Abstract

Softening and subsequent flowing of resist during postexposure baking, used to promote resist adhesion, often results in reduced resolution and linewidth control. This is unacceptable for the fabrication of very fine feature VLSI devices since linewidth variations of 0.5–1.5 μm can be observed under certain baking conditions. Treatment of positive and negative resists with a nitrogen plasma prior to postbaking reduces resist flow significantly and enables linewidth integrity to be maintained. Minimal resist erosion occurs upon plasma treatment. In one example a series of 1.4-μm-diam windows were exposed and developed in 0.8-μm-thick HPR-204 positive photoresist. Samples treated with a 400 W unshielded nitrogen plasma for 10 min exhibited no change in feature width whereas the untreated control, baked as above, exhibited completely closed windows due to excessive resist flow. A model is proposed to account for the improved flow characteristics.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.