Abstract
The results of experiments on the extrinsic magnetic field influence on high-impedance plasma opening switch (POS) operation are reported. It has been demonstrated that POS voltage could be increased by the factor of 1.5 using an extrinsic magnetic field at erosion regime. The requirements for the magnetic field value and POS parameters to achieve maximum POS voltage have been determined. The experimentally tested dependency of the POS switching voltage as a function of the Marx one is presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.