Abstract
In this paper we presented experimental investigation of effects of local limiter biasing (Vbiasing = +200 v, Vbiasing = +320 v) on the plasma parameters as plasma current, loop voltage, poloidal beta, plasma pressure, plasma energy, plasma resistance, plasma temperature, plasma displacement, Shafranov parameter and plasma internal inductance in IR-T1 tokamak. For these purposes, array of magnetic probes and also a diamagnetic loop have been used. The results show that applied biased voltage Vbiasing = +200 v causes to decrease of about 40 % in plasma internal inductance. The plasma resistance and the plasma displacement have been decreased by Vbiasing = +200 v. The main result of the application of Vbiasing = +200 v is flatting the plasma parameters profiles. In other words, the addition of biasing voltage Vbiasing = +200 v to plasma could be effective for improving the quality of tokamak plasma discharge by creating the steady state plasma. The plasma current, plasma pressure, plasma energy, plasma temperature and shift parameter have increased after the application of limiter biasing with Vbiasing = +320 v but they decrease rapidly.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.