Abstract
Due to the shortage of personal protective equipment (PPE) during the COVID-19 pandemic, the interest and demand for sterilization devices to reuse PPE has increased. For reuse of face masks, they must be effectively decontaminated of potential infectious agents without compromising its filtration ability during sterilization. In this study, we utilized an atmospheric pressure pulsed dielectric barrier discharge (DBD), combined with nebulized liquid microdroplets to generate plasma-activated mist (PAM). MS2 and T4 bacteriophages were used to conduct the decontamination tests on two types of N95 respirators. Results showed at least a 2-log reduction of MS2 and T4 on N95 respirators treated in one cycle with 7.8% hydrogen peroxide PAM and at least a 3-log reduction treated in 10% hydrogen peroxide PAM. In addition, it was found that there was no significant degradation in filtration efficiency of N95 respirators (3M 1860 and 1804) treated in 10% hydrogen peroxide PAM found after 20 cycles. In terms of re-useability of masks after treatment as determined, it was shown that the elastic straps of 3M 1804 were fragmented after 20 treatment cycles rendering them unusable, while the straps of 3M 1860 were not negatively affected even after 20 disinfection cycles.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.