Abstract

This study demonstrated the use of quadrupole mass spectrometer (QMS) and optical emission spectrometer (OES) in diagnosing plasma process of electron cyclotron resonance chemical vapor deposition (ECR-CVD) process. The result showed that, by adjusting main magnetic coil current in ECR-CVD system, the relationship between plasma chemical composition and magnetic field was discussed in this paper. As the results, by controlling appropriate magnetic field configuration, the characteristics of a-Si:H thin film such as photosensitive, microstructure and deposition rate could be improved.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.