Plasma parameters in Plasma Cathode Electron Source Device (PCESD) are very important things because they will determine the eficiency of its electron extraction. Square pulse mode of PCESD’s arc discharge plasma current can be obtained by using Pulse Forming Network (PFN) circuits which is called Arc Discharge Power Supply (ADPS). The square pulse mode is necessity to simplify in electron irradiation dose calculation. ADPS is connected with Hollow Anode Chamber (HAC) which is placed inside of PCESD to produce arc discharge plasma. The value of arc discharge plasma current is the main key to determine plasma parameters that can be measured by using Rogowski coil. The value of the arc discharge plasma current is IADPS = 206.30 A with pulse width  = 80 μs. Whereas the plasma parameters values inside of the HAC are: the electron plasma density ne = (16.85  1019) m-3, electron plasma temperature Te = 2.609 eV, electron plasma frequency fe = 116.74 GHz, and Debye length λD = 9.958 µm respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.