Abstract
A technique has been developed for measuring the properties of discharge-based plasma channels by monitoring the centroid location of a laser beam exiting the channel as a function of input alignment offset between the laser and the channel. Experiments were performed using low-intensity (<1014 W cm−2) laser pulses focused onto the entrance of a hydrogen-filled capillary discharge waveguide. Scanning the laser centroid position at the input of the channel and recording the exit position allow determination of the channel depth with an accuracy of a few percent, measurement of the transverse channel shape, and inference of the matched spot size. In addition, accurate alignment of the laser beam through the plasma channel is provided by minimizing laser centroid motion at the channel exit as the channel depth is scanned either by scanning the plasma density or the discharge timing. The improvement in alignment accuracy provided by this technique will be crucial for minimizing electron beam pointing errors in laser plasma accelerators.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.