Abstract

The aim of this study is to investigate the feasibility, effectiveness, and safety of placement of intracoronary stents mounted on “over the wire” balloon catheters without using long guidewires. Fifteen consecutive patients underwent GR II stent placement. Over the wire balloon catheters and short guidewires were used. The new method was successful in 14 of 15 cases. No complications were observed. This novel technique using a short (instead of long) guidewire to place intracoronary stents mounted on over the wire balloon catheters was successful, and more convenient. (J Interven Cardiol 2000; 13:27–30)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.