An ultra-high speed, time-resolved particle image velocimetry (PIV) system is developed to measure velocity fields created by explosive detonators. When initiated into a gas, the detonators generate blast waves that propagate outwards from the origin of initiation at supersonic speeds. The PIV system consists of a custom eight-pulse Nd:YAG laser system and an ultra-high speed camera system comprising four dual-frame CCD cameras optically combined to share a single optic axis. The system is capable of sampling the flow field four times at up to 333 MHz or eight times at up to 8 MHz. System development is discussed, and preliminary application to the complex flow behind the blast wave from an exploding bridge wire detonator is demonstrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.