Abstract

The objective was to analyze the management of intraoperative CSF leaks in transsphenoidal surgeries to prevent postoperative cerebrospinal fluid (CSF) leaks. Sixty-three pituitary tumors were operated by transnasal approach. In presence of arachnoidal opening, a fat graft was placed into the sellar cavity, followed by collagen sponge layer and fibrin glue. The sphenoid sinus was also packed with fat graft and collagen sponge. An external CSF lumbar drainage was kept for 2-4 days. The variables analyzed were: intraoperative and postoperative CSF leaks, procedures, and related complications. The overall incidence of postoperative CSF leak was 1.5%. Twenty patients (31.7%) had intraoperative arachnoidal opening, 5% of whom had postoperative CSF leak. There were no reoperations because of CSF leak, and no secondary intrasellar arachnoidoceles. Mean follow-up was 3.6 years. The preventive treatment had good results and there were no complications related to the intervention strategy, encouraging us to continue performing this simple, effective, and inexpensive procedure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call