Abstract

Lau et al. [J. Neurosci. 37, 9013-9021 (2017)] showed that discrimination of the fundamental frequency (F0) of complex tones with components in a high-frequency region was better than predicted from the optimal combination of information from the individual harmonics. The predictions depend on the assumption that psychometric functions for frequency discrimination have a slope of 1 at high frequencies. This was tested by measuring psychometric functions for F0 discrimination and frequency discrimination. Difference limens for F0 (F0DLs) and difference limens for frequency for each frequency component were also measured. Complex tones contained harmonics 6-10 and had F0s of 280 or 1400 Hz. Thresholds were measured using 210-ms tones presented diotically in diotic threshold-equalizing noise (TEN), and 1000-ms tones presented diotically in dichotic TEN. The slopes of the psychometric functions were close to 1 for all frequencies and F0s. The ratio of predicted to observed F0DLs was around 1 or smaller for both F0s, i.e., not super-optimal, and was significantly smaller for the low than for the high F0. The results are consistent with the idea that place information alone can convey pitch, but pitch is more salient when phase-locking information is available.