Leaks from pipes and valves are a reputational issue in industry. Maintenance of pipeline integrity is becoming a growing challenge due to the serious socioeconomic consequences. This paper presents a secondary phase transform (PHAT) cross-correlation method to improve the performance of the acoustic methods based on cross-correlation for pipeline leakage detection. Acoustic emission signals generated by pipe leakage are first captured by the sensors at different locations, and are subsequently analyzed using the cross-correlation curve to determine whether leakage is occurring. When leakage occurs, time delay estimation (TDE) is further carried out by peak search in the cross-correlation curve between the two sensor signals. In the analysis, the proposed method calculates the secondary cross-correlation function before the PHAT operation. A sinc interpolation method is then introduced for automatic searching the peak value of the cross-correlation curve. Numerical simulations and experimental results confirm the improved performance of the proposed method for noise suppression and accurate TDE compared to the basic cross-correlation method, which may be beneficial in engineering applications.