Abstract

Pipe internal recirculation (PIR) is an undesired phenomenon which may lead to significant additional heat losses. Although different research institutes already measured singular PIR effects, there is still a lack of wide-ranging evaluations and practical solutions.This paper describes a test and evaluation method and reports on results regarding the influence of the pipe’ slope, the material (copper, stainless steel) and diameter on the PIR caused heat loss coefficient. For combined pipe path arrangements a new method is presented, which allows to calculate the heat losses from basic investigations on horizontal and vertical pipe orientations. This method has been experimentally validated. Finally, the effectiveness of different measures for the reduction of PIR induced heat losses is presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.