Abstract

Simultaneous endoscopic third ventriculostomy (ETV) and tumor biopsy is a widely accepted therapeutic and diagnostic procedure for patients with noncommunicating hydrocephalus secondary to a pineal region tumor. Multiple approaches have been advocated, including the use of a steerable fiberoptic or rigid lens endoscope via 1 or 2 trajectories. However, the optimal approach has not been established based on the individual anatomical characteristics of the patient. A retrospective review of patients undergoing simultaneous ETV and tumor biopsy was undertaken. Preoperative MR images were examined to measure the width of the anterior third ventricle and maximal diameters of the tumor, Monro foramen (right), and massa intermedia. The distances between the tumor and massa intermedia, tumor and anterior commissure, midbrain and massa intermedia, and the dorsum sella and anterior commissure were also recorded. Single and dual trajectory approaches were compared using paired t-tests for each parameter. Over an 8-year interval, 15 patients underwent simultaneous ETV and tumor management. These patients ranged from 6 to 71 years of age (mean 36.7 years); 5 were younger than 18 years of age. Seven were treated using a dual trajectory approach, and 8 were treated using a single trajectory approach. All cases were completed without complications or the need for an additional CSF diversionary procedure within 6 months. The diagnostic yield at biopsy was 86.7%. There were no statistically significant differences between the single and dual trajectory groups for the measured parameters. However, the dual trajectory group demonstrated a larger anterior third ventricular diameter (1.43 vs 1.21 cm, p = 0.29). The single trajectory group trended toward a smaller tumor-anterior commissure interval (2.23 vs 2.51 cm, p = 0.24) and a larger dorsum sella-anterior commissure distance (1.67 vs 1.49 cm, p = 0.28). These data confirm the safety and diagnostic efficacy of simultaneous ETV and biopsy for tumors of the pineal region. Although no statistically significant differences were seen in the authors' recorded measurements, several trends suggest a role for a tailored approach to selecting a single or dual trajectory approach when using a rigid endoscope.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.