Abstract
A pilot-scale continuous Chromatograph has been developed for optimization studies and scaling factor evaluations. The continuous annular Chromatograph consists of a slowly rotating annular bed of ion exchange resin to which feed is continuously introduced at a stationary point at the top of the bed while eluent flows over the remainder of the annulus. The rotation of the sorbent bed coupled with the simultaneous elution chromatography causes the separated components of the feed stream to appear as helical bands, each of which has a characteristic, stationary exit point.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.