Abstract

BackgroundToilet surfaces are contaminated with pathogens, and they may be a vector for disease transmission. In this study, we investigated the efficacy of an automated 222-nm ultraviolet C (UVC) disinfection device “Care222™,” with a motion sensor, for removing bacterial contamination in a shared bathroom. MethodsTwo automated UVC devices, deactivated by motion sensors, were mounted on the ceiling of two bathrooms; the emission window of the UVC device was covered in the non-treated bathroom. After irradiation, samples were collected from five surfaces at four time points/day for 5 days, and colony-forming units (CFUs) of aerobic bacteria (AB) were determined. The irradiation time was also measured. ResultsUVC source deactivation time did not significantly differ between the bathrooms. There was a significant difference in the total AB CFUs between the treated and non-treated bathrooms. In the treated bathroom, the CFUs of AB of the toilet seat, control panel of the electric toilet seat, and top of the toilet paper holder were significantly lower than those of the control. The CFUs of AB at 9:00, 15:00, and 18:00 h in the treated bathroom were significantly lower than those of the control. ConclusionsThe automated 222-nm UVC disinfection device with a motion sensor significantly reduced AB surface contamination of a shared bathroom.