Abstract
We have designed and installed a pillow seal system for the BigRIPS fragment separator at the RIKEN Radioactive Isotope Beam Factory (RIBF) to facilitate remote maintenance in a radioactive environment. The pillow seal system is a device to connect a vacuum chamber and a beam tube. It allows quick attachment and detachment of vacuum connections in the BigRIPS separator and consists of a double diaphragm with a differential pumping system. The leakage rate achieved with this system is as low as 10–9Pam3/s. We have also designed and installed a local radiation-shielding system, integrated with the pillow seal system, to protect the superconducting magnets and to reduce the heat load on the cryogenic system. We present an overview of the pillow seal and the local shielding systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.