Abstract

The pencil lead break (PLB) is a well-known method for characterizing acoustic emission sensors. In this paper, we analyze the effectiveness of this method in characterizing piezoelectric transducers for structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique. Tests were carried out on aluminum beams of different sizes, and two types of transducers were considered: lead zirconate titanate ceramics and macrofiber composite devices. The experimental results indicate a clear relationship between the variation in the electrical impedance signature of the transducer and power spectral density obtained with the PLB method. Therefore, the PLB can be a simple and effective method for assessing the sensitivity of transducers for damage detection in SHM systems based on the EMI technique.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.