Abstract
AbstractVarious fullerene C60‐proteins such as C60‐myoglobin (C60‐Mb), C60‐hemoglobin (C60‐Hb) and C60‐gliadin, coated piezoelectric quartz crystals were prepared and applied in piezoelectric quartz crystal immunosensors for protein‐antibodies such as anti‐myoglobin (Anti‐Mb), anti‐hemoglobin (Anti‐Hb) and anti‐gliadin respectively. The immobilizations of myoglobin, hemoglobin and gliadin onto Fullerene C60 were studied with a C60‐coated piezoelectric crystal detection system, respectively. The partially irreversible frequency responses for theses proteins were observed by a desorption study, implying that C60 can strongly adsorb these proteins. Thus, immobilized C60‐Mb, C60‐Hb and C60‐gliadin coating materials were successfully prepared and identified with FTIR spectrometry. The C60‐Mb, C60‐Hb and C60‐gliadin coated piezoelectric (PZ) quartz crystal immunosensors with homemade computer interfaces for signal acquisition and data processing were developed and applied for detection of Anti‐Mb, Anti‐Hb and anti‐gliadin respectively. The C60‐protein coated PZ immunosensors for Anti‐Mb, Anti‐Hb and antigliadin exhibited linear frequency responses to the concentrations of theses anti‐proteins with sensitivities of 1.43 × 103, 2.59 × 103 and 8.05 × 103 Hz/(mg/mL) respectively. The detection limits of these PZ‐immunosensors were 4.36 × 10−3, 3.23 × 10−3 and 1.98 × 10−3 mg/mL for Anti‐Mb, Anti‐Hb and anti‐gliadin respectively. Effects of pH and temperature on the frequency responses of the anti‐protein PZ‐immunosensors were also investigated. The optimum pH of these anti‐proteins and the optimum temperature for the PZ‐immunosensors were observed at pH = 7 and around 30 °C respectively. The interferences of various common species in human blood, e.g., cysteine, tyrosine, urea, glucose, ascorbic acid and metal ions, to these anti‐protein PZ‐immunosensors were also investigated respectively. These species showed nearly no interference or quite small interference with the anti‐protein PZ‐immunosensors. The reproducibility and lifetime of these immobilized C60‐protein coated PZ crystal immunosensors were also investigated and discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.