Abstract

<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> A picture-based high-speed address recovery technique for ac plasma display panels (PDPs) is proposed. By removing the ground (GND) switching operation, the recovery speed can be increased and the switching loss due to the GND switch is reduced. The proposed method can perform load-adaptive operations by controlling the voltage level of the energy recovery capacitor, which prevents the increase of inefficient power consumption caused by circuit loss during the recovery operation. Thus, the technique shows the minimum address power consumption according to various displayed images, which is different from previous methods operating in fixed mode regardless of images. Test results with a 50-in HD single-scan PDP (<formula formulatype="inline"><tex>$\hbox{resolution} = 1366 \times 768$ </tex></formula>) show that a recovery time of less than 350 ns is successfully accomplished and about 54% of the maximum power consumption can be reduced, by tracing the minimum power consumption curves. </para>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.