Abstract
For several years we have been studying the use of Fabry-Perot interferometers for precise measurement of the refractive index of gasses, where the primary motivation has been to improve interferometer-based length measurement. Because the refractive index of a gas depends on its pressure and temperature, we can also use refractive index to monitor either of these quantities if the second is known. Recently we have embarked on a project that will utilize refractive index to infer pressure with a smaller measurement uncertainty than is currently possible, hoping to reach a relative standard uncertainty of 1.4™~10-6. The projected uncertainty budget is currently dominated by uncertainty of the Boltzmann constant, but following the coming redefinition of SI units, the Boltzmann uncertainty will be replaced by uncertainty in the temperature scale, at which point refractive index measurements can be expected to play a central role in precise realization of thermodynamic temperature. Dimensional metrology with picometer uncertainties is the core of our technique and is the subject of this paper. Refractive index will be measured by comparing two precisely equal displacements ( .150 mm), where one displacement is in vacuum and the second is in helium and will appear to be slightly longer due to the refractive index. The two displacements must be compared with < 3 pm uncertainty. The intrinsic precision achievable with Fabry-Perot cavities far exceeds our needed accuracy, but two or more independent interferometers have never been compared to such high accuracy when undergoing macroscopic displacements. The major challenges include many of the typical sources of error in dimensional measurement, such as Abbe errors, alignment errors, material dimensional stability, etc. Careful consideration must be given to second-order effects that are not normally large enough to merit mention. Our proposed experimental design will minimize such errors and provide additional metrology (including angle measurements with nanoradian precision) needed to correct the residual errors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.