This is a rare case of a peripherally inserted central catheter (PICC) that was found to be in the pericardiacophrenic vein on a post-procedure chest X-ray. An 82-year-old man was admitted to the medical ICU for severe sepsis with shock and a PICC was placed for vasopressor support. Malpositioning of a central venous catheter can lead to catastrophic results including, perforation, pericardial effusion and tamponade.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.