Abstract

This work presents a novel demonstration-scale integration of a 36-m2 Fresnel solar collector in urban wastewater reclamation. A prototype plant was designed and installed to study Escherichia coli and total coliforms disinfection in continuous flow mode. The plant modelling was empirically addressed, resulting in different linear first-order models, which were used to design a PI-based cascade control approach for the automatic operation of the photoreactor. Considering EU 2020/741 Regulation, water quality Class D and Class A were achieved when operating the upgraded design of the plant at 50°C (200 L/h) and 60°C (150 L/h), respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.