Abstract

JET has been operating for one year. The diagnostic capability has been progressively increased from the barely adequate initial level to the point where physics data on the internal plasma processes is available. The plasma current has been taken up to just over 3 MA with flat-top times of several seconds. Central electron temperatures are in the range 1-3 keV, mean electron densities (n) from 0.1-2.5*1019m-3 and the derived global energy confinement tau epsilon reaches 0.35s+or-30%. The radiation loss is substantial, ranging from 60-100% of the input power. The contamination of the plasma is high, giving typical values of Zeff approximately 5, limiting the maximum density, giving higher temperatures and lower (n tau epsilon ) products than expected. Experiments and machine changes are in hand to overcome this problem.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.