Abstract

The alumina contains plenty of Li2O and K2O as a result of using low-grade bauxite in China. Thus, LiF and KF will be enriched in the electrolytes with the operation of the cell, so that the composition and physicochemical properties of electrolytes have been changed. The effects of LiF, KF, and CR on the liquidus temperature of electrolytes based on the xNaF·AlF3-5 wt pct CaF2-2.5 wt pct Al2O3-0.5 wt pct MgF2 system have been investigated in this study. The results show that the liquidus temperature decreases by 5.13 K to 10.74 K (5.13 °C to 10.74 °C) per 1 wt pct addition of LiF and that the liquidus temperature decreases by 1.63 K to 3.8 K (1.63 °C to 3.8 °C) with per 1 wt pct addition of KF. When adding LiF and KF together, it has the interplay between LiF and KF. Under different electrolyte systems, the interplay between LiF and KF is complex. The effect of CR on liquidus temperature has been related to the concentration of LiF and KF.