Abstract

ABSTRACTScrap material recovery and recycling companies are producing wastewater in which common pollutants (such as COD, nutrients and suspended solids), toxic metals, polyaromatic hydrocarbons (PAH) and polychlorinated biphenyls (PCB) frequently can exceed the discharge limits. Lab-scale optimisation of different possible physical–chemical treatment techniques was performed on the wastewater originating from three different companies in view of further testing at pilot-scale testing and implementation at full-scale. The lab-scale tests demonstrate that sedimentation or hydrocyclone treatment as stand-alone technique cannot be used for proper treatment of this type of wastewater. Dual bed filtration or coagulation/flocculation proved to be more promising with removal efficiencies of about 71–95% (dual bed filtration) and 61–97% (coagulation/flocculation) for the above-mentioned pollutants (metals, PAH and PCB).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.