Physical outcome measures for conductive and mixed hearing loss treatment: A systematic review.

  • Abstract
  • Literature Map
  • Similar Papers
Abstract
Translate article icon Translate Article Star icon

The number of potential options for rehabilitation of patients with conductive or mixed hearing loss is continually expanding. To be able to inform patients and other stakeholders, there is a need to identify and develop patient-centred outcomes for treatment of hearing loss. To identify outcome measures in the physical core area used when reporting the outcome after treatment of conductive and mixed hearing loss in adult patients. Systematic review. Systematic review of the literature related to reported physical outcome measures after treatment of mixed or conductive hearing loss without restrictions regarding type of intervention, treatment or device. Any measure reporting the physical outcome after treatment or intervention of mixed or conductive hearing loss was sought and categorised. The physical outcome measures that had been extracted were then grouped into domains. The literature search resulted in the identification of 1434 studies, of which 153 were selected for inclusion in the review. The majority (57%) of papers reported results from middle ear surgery, with the remainder reporting results from either bone conduction hearing devices or middle ear implants. Outcomes related to complications were categorised into 17 domains, whereas outcomes related to treatment success was categorised into 22 domains. The importance of these domains to patients and other stakeholders needs to be further explored in order to establish which of these domains are most relevant to interventions for conductive or mixed hearing loss. This will allow us to then assess which outcome measures are most suitable for inclusion in the core set.

Similar Papers
  • Research Article
  • Cite Count Icon 8
  • 10.3109/00206098909081623
Brains tern Electric Response Audiometry: Estimation of the Amount of Conductive Hearing Loss with and without Use of the Response Threshold
  • Jan 1, 1989
  • International Journal of Audiology
  • J.F.C Van Der Drift + 2 more

Three aspects of brainstem response audiometry were investigated in the present study. (1) The brainstem response threshold was compared with the pure-tone audiogram in 40 patients with conductive hearing loss. The brainstem response threshold has a one-to-one relationship with the mean of the pure-tone thresholds at 2 and 4 kHz. The correlation coefficient in this comparison is 0.84 and the standard error of the estimate is 8.3 dB. Taking into account corresponding results in cochlear hearing loss [Drift et al.: Audiology 26: 1-10, 1987] it is concluded that the brainstem response threshold provides a good estimate of the amount of peripheral hearing loss, independent of the type of hearing loss. (2) It was shown [Drift et al.: Audiology 27: 260-270, 1988] that different types of peripheral hearing loss can be distinguished reliably with brainstem response audiometry. Parameters relevant for this distinction were the horizontal shift of the latency-level curve (1(L) curve), that of its derivative and the response threshold. In the clinical situation measurement of the response threshold is not always possible due to restlessness of the patient. To simulate this situation we randomly truncated the lower parts of the 1(L) curves of quiet patients. The test group consisted of 22 adult normally hearing subjects, 79 patients with cochlear hearing loss, 40 with conductive hearing loss and 22 with mixed hearing loss. Linear discriminant analysis was applied to the horizontal shift of the 1(L) curve and of its derivative. The brainstem diagnosis 'normal hearing' correctly excludes a conductive hearing loss in 98% of the cases and the brainstem diagnosis 'cochlear hearing loss' does so in 79%. The brainstem diagnosis 'conductive hearing loss' correctly predicts a conductive component of hearing loss in 94% of the cases and the brainstem diagnosis 'mixed hearing loss' does so in 90%. The distinction between cochlear hearing loss and normal hearing is not reliable, neither is the distinction between conductive and mixed hearing loss. (3) The amount of the conductive component of hearing loss can be estimated by the horizontal shift of the 1(L) curve. Statistical comparison with the mean of the air-bone gaps at 2 and 4 kHz gave a correlation coefficient of 0.77, a standard error of the estimate of 9.7 dB, and a slope of the regression line of 0.93. An overestimation of about 7 dB has to be taken into account in case of mixed hearing loss.

  • Research Article
  • Cite Count Icon 1
  • 10.1016/j.ijporl.2024.112027
Characterization of hearing loss in pediatric patients with osteogenesis imperfecta
  • Jul 6, 2024
  • International Journal of Pediatric Otorhinolaryngology
  • Chelsea Cleveland + 3 more

Characterization of hearing loss in pediatric patients with osteogenesis imperfecta

  • Research Article
  • Cite Count Icon 34
  • 10.1016/j.ijporl.2018.12.026
The Bonebridge implant in older children and adolescents with mixed or conductive hearing loss: Audiological outcomes
  • Dec 21, 2018
  • International Journal of Pediatric Otorhinolaryngology
  • Anna Ratuszniak + 3 more

The Bonebridge implant in older children and adolescents with mixed or conductive hearing loss: Audiological outcomes

  • Research Article
  • Cite Count Icon 29
  • 10.1002/lary.24474
Vibroplasty in mixed and conductive hearing loss: Comparison of different coupling methods
  • Dec 13, 2013
  • The Laryngoscope
  • Erich Vyskocil + 7 more

To evaluate modified coupling techniques of the Vibrant Soundbridge system in patients with mixed and conductive hearing loss and to compare it with conventional vibroplasty. Retrospective study. Two different groups were evaluated: 1) nine cases of conventional incus vibroplasty in comparison with 2) nine patients with modified coupling of the floating mass transducer. In the modified coupling approach, the vibrant floating mass transducer was attached to 1) the stapes/oval window, 2) the round window, or 3) the drilled promontory bone (promontory fenestration window). In three patients, an additional ossiculoplasty was performed. Preoperative and postoperative aided and unaided pure-tone and free-field audiometry and Freiburg monosyllabic word test were used to assess hearing outcome. Functional hearing gain obtained in patients with mixed and conductive hearing loss who underwent modified coupling was 39 dB. Patients with pure sensorineural hearing loss who received conventional incus coupling showed a functional hearing gain of 25 dB. Average functional gain was 41 dB in the oval window group, 45 dB in the round window group, and 30 dB in the promontory fenestration window group. Word recognition test revealed an average improvement of 51% and 21% in the modified and in the conventional approach, respectively. Modified vibroplasty is a safe and effective treatment for patients with conductive and mixed hearing loss. Coupling the floating mass transducer to the promontory bone (promontory fenestration window) is a viable option in chronically disabled ears if oval and round window coupling is not possible. 4.

  • Research Article
  • Cite Count Icon 90
  • 10.1007/s00405-016-4228-6
Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use.
  • Jul 30, 2016
  • European Archives of Oto-Rhino-Laryngology
  • Sébastien Schmerber + 13 more

The objective of this study is to evaluate the safety and efficacy of a new transcutaneous bone-conduction implant (BCI BB) in patients with conductive and mixed hearing loss or with single-sided deafness (SSD), 1year after surgical implantation. The study design is multicentric prospective, intra-subject measurements. Each subject is his/her own control. The setting is nine university hospitals: 7 French and 2 Belgian. Sixteen subjects with conductive or mixed hearing loss with bone-conduction hearing thresholds under the upper limit of 45dB HL for each frequency from 500 to 4000Hz, and 12 subjects with SSD (contralateral hearing within normal range) were enrolled in the study. All subjects were older than 18years. The intervention is rehabilitative. The main outcome measure is the evaluation of skin safety, audiological measurements, benefit, and satisfaction questionnaires with a 1-year follow up. Skin safety was rated as good or very good. For the mixed or conductive hearing loss groups, the average functional gain (at 500Hz, 1, 2, 4kHz) was 26.1dB HL (SD 13.7), and mean percentage of speech recognition in quiet at 65dB was 95% (vs 74% unaided). In 5/6 SSD subjects, values of SRT in noise were lower with BB. Questionnaires revealed patient benefit and satisfaction. The transcutaneous BCI is very well tolerated at 1-year follow up, improves audiometric thresholds and intelligibility for speech in quiet and noise, and gives satisfaction to both patients with mixed and conductive hearing loss and patients with SSD.

  • Research Article
  • Cite Count Icon 1
  • 10.7874/kja.2014.18.1.13
Conductive and Mixed Hearing Losses: A Comparison between Summer and Autumn
  • Apr 1, 2014
  • Korean Journal of Audiology
  • Mansoureh Nickbakht + 1 more

Background and ObjectivesConductive hearing loss is common among children and adults. This study aims at comparing the results of conductive hearing loss in summer and autumn.Subjects and MethodsPuretone audiometry and tympanometry tests were done for all patients who referred to the Iranian-based audiology center of Imam Khomeini Hospital in Ahvaz. Data on the patients with conductive or mixed hearing loss were analyzed. The impacts of season, age, and etiology of the disease were analyzed on the patients who visited the audiology clinic due to the conductive hearing loss in summer and autumn.ResultsOne hundred and fifty nine patients in summer and 123 patients in autumn had conductive or mixed hearing loss. Their age ranged from four to 82 years, with the average age of 35. The percentage of the patients, with acute otitis media and chronic otitis media (COM), who visited this clinic, was significantly higher than those with middle ear problems. COM and mastoid surgeries rate was higher in summer than autumn among adults.ConclusionsThere is no relationship between season and middle ear diseases between children and juveniles, but COM and mastoid problems are more common in summer among adults visiting this clinic. Most of the patients had mild conductive hearing loss and bilateral middle ear impairments.

  • Research Article
  • Cite Count Icon 46
  • 10.1159/000322647
Functional Results of Vibrant Soundbridge Middle Ear Implants in Conductive and Mixed Hearing Losses
  • Jan 13, 2011
  • Audiology and Neurotology
  • Daniele Bernardeschi + 6 more

Objective: Our purpose was to evaluate the results of Vibrant Soundbridge (VSB) in conductive or mixed hearing loss. Materials and Methods: Twenty-five adult patients (29 ears) with a mixed or conductive hearing loss and various etiologies were included in this retrospective study. The preoperative ipsilateral pure tone average was 71 ± 3.0 dB, and the average bone conduction threshold was 42 ± 2.8 dB (n = 29). The transducer was placed on the long apophysis of the incus (n = 16), in the round window (n = 10) or on the stapes (n = 3). Results: No complications were noted. The bone conduction threshold remained unchanged. VSB was activated in all cases. The postoperative pure tone average without VSB was 63 ± 3.9 dB (n = 24) and with VSB in free-field condition 24 ± 2.1 dB (n = 22). Conclusions: VSB is safe and efficacious for auditory rehabilitation in conductive and mixed hearing losses.

  • Research Article
  • Cite Count Icon 4
  • 10.1080/14992027.2021.1872805
Psychosocial outcome measures for conductive and mixed hearing loss treatment: An overview of the relevant literature
  • Feb 22, 2021
  • International Journal of Audiology
  • Amberley V Ostevik + 8 more

Objective To identify the psychosocial assessments utilized with individuals with conductive and/or mixed hearing loss as part of a broader effort by the Auditory Rehabilitation Outcomes Network (AURONET) group to develop a core set of patient-centred outcome measures. Design A review of articles published between 2006 and 2016 was completed. Included studies had more than three adult participants, were available in English, and reported a psychosocial outcome from any treatment of mixed and/or conductive hearing loss. Study sample Sixty-six articles from seven databases. Results Sixty-six articles met our inclusion/exclusion criteria. Within this set, 15 unique psychosocial or patient-reported outcome measures (PROs) were identified, with the Abbreviated Profile of Hearing Aid Benefit (APHAB) and Glasgow Benefit Inventory (GBI) being the most frequently dispensed. Five of the fifteen were only administered in one study. In-house questionnaires (IHQs) were reported in 19 articles. Conclusions Only 66 (22%) of the 300 articles with outcomes contained a PRO. Some of the mostly frequently employed PROs (e.g., APHAB) were judged to include only social items and no psychological items. Lack of PRO standardization and the use of IHQs make psychosocial comparisons across treatments in this population difficult for patients, clinicians and stakeholders.

  • Research Article
  • Cite Count Icon 5
  • 10.1097/rct.0b013e3182ab2afb
The Prevalence of Superior Semicircular Canal Dehiscence in Conductive and Mixed Hearing Loss in the Absence of Other Pathology Using Submillimetric Temporal Bone Computed Tomography
  • Jan 1, 2014
  • Journal of Computer Assisted Tomography
  • Young Hen Lee + 4 more

The objective of this study was to assess the relationship between superior semicircular canal dehiscence (SSCD) and hearing impairment. We retrospectively compared the prevalence of SSCD in the ears classified as conductive hearing loss (CHL), mixed hearing loss (MHL), and normal hearing status using submillimetric temporal bone computed tomography (TBCT) on the basis of coronal and additional reformatted planes dedicated to SSCD. From the patients with CHL (n = 127) and MHL (n = 45), the overall prevalence of SSCD in the ears classified as CHL, MHL, and normal hearing status were 6.6%, 7.2%, and 3.0%, respectively. Furthermore, the odds ratio for SSCD in the absence of any cause of hearing loss (eg, dysfunction of the tympanic membrane or middle ear, TBCT abnormalities, otosclerosis, trauma, surgery) was 5.35 in MHL (4/27; P = 0.037, 95% confidence interval, 1.1-25.81) and 3.31 in CHL (5/61; P = 0.115, 95% confidence interval, 0.75-14.63), compared with normal hearing status. Bony covering of the SSC should be specifically evaluated in patients with hearing impairment using submillimetric TBCT.

  • Research Article
  • 10.1044/leader.ftr7.14092009.5
New Bone-Anchored Amplification Options for Children
  • Jul 1, 2009
  • The ASHA Leader
  • Lisa Christensen

New Bone-Anchored Amplification Options for Children

  • Research Article
  • Cite Count Icon 1
  • 10.1177/00368504241280252
The impact of the Cochlear™ Osia® 2 System on patients with mixed or conductive hearing loss: A comparison with Cochlear™ Baha® Attract System outcomes
  • Jul 1, 2024
  • Science Progress
  • Kyeong-Suk Park + 3 more

ObjectiveThis prospective study assessed the efficacy of the Cochlear™ Osia® 2 System compared to the previous Baha® Attract System in patients with mixed or conductive hearing loss (MHL/CHL).MethodsIn this prospective case-control study, 10 patients (2 men and 8 women) with MHL/CHL were implanted with the Osia® 2 System. Their audiological outcomes were compared with 13 patients (2 men and 11 women) who had previously been implanted with the transcutaneous Baha® Attract system. We compared the complications and compliance of the two groups. Also, in the Osia 2 System group, subjective satisfaction was assessed using the Korean version of the International Outcome Inventory for Hearing Aids (K-IOI-HA) questionnaire and the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire.ResultsComplications such as poor magnetization, pain & infection, and abnormal noise were more common in the Baha Attract group, although not statistically significant. Also, the Osia 2 group exhibited better compliance. Subjective satisfaction was assessed using the K-IOI-HA and APHAB questionnaires with the Osia 2 group, revealing significantly improved scores in ease of communication, reverberation, background noise, and higher K-IOI-HA scores post-implantation. Postoperative-aided thresholds with both systems were significantly lower than preoperative-unaided thresholds, with the Osia 2 System demonstrating notably high satisfaction levels. Although both systems showed similar preoperative and postoperative word-recognition scores, the Osia 2 System provided greater audiological gain, especially at 2 kHz and 4 kHz frequencies. Additionally, the functional gain of both systems was comparable across all frequencies.ConclusionsThe Osia 2 System demonstrated high subjective satisfaction and improved audiological outcomes compared to the Baha Attract system in patients with conductive or mixed hearing loss. Its superior audiological gain, particularly at critical frequencies, along with better compliance, suggests it as a favorable option for this patient population.

  • Research Article
  • Cite Count Icon 23
  • 10.1542/pir.35-11-456
Pediatric hearing loss.
  • Oct 31, 2014
  • Pediatrics in Review
  • Christopher R Grindle

On the basis of strong research, universal newborn screening should be performed before age 1 month with repeat or follow-up testing for those who do not pass performed before age 3 months and intervention started before age 6 months. On the basis of strong research and consensus statement, tympanostomy tubes should be considered for individuals with bilateral persistent middle ear effusion for 3 months or greater and a documented conductive hearing loss. On the basis of consensus statement, all children with suspected hearing loss should have an age appropriate hearing test. On the basis of strong research, the most common form of congenital hearing loss is genetic. Most of this is nonsyndromic hearing loss.

  • Research Article
  • Cite Count Icon 28
  • 10.1055/s-0031-1286321
Das aktive Mittelohrimplantat in der Rehabilitation von sensorineuralen, kombinierten und Schallleitungs-Hörstörungen
  • Sep 1, 2011
  • Laryngo-Rhino-Otologie
  • G Sprinzl + 3 more

Active middle ear implants, such as the Vibrant Soundbridge, are used as an important part in the rehabilitation of sensorineural, conductive hearing, or mixed hearing loss. The attachment of the Vibrant Soundbridge at the round window and the usage of the Vibroplasty couplers strongly expanded the application of the Vibrant Soundbridge.The Vibrant Soundbridge is developed for patients who have an intolerance to hearing aids and a moderate to profound sensorineural hearing loss. The VSB also provides an optimal solution for patients with failed middle ear reconstructions or patients with atresia. To capture the improvement with the VSB Implant with different hearing losses a literature analysis was conducted. The functional gain was analyzed for 107 patients with conductive hearing loss and for 214 patients with sensorineural hearing loss out of 14 studies.Patients with conductive and mixed hearing loss resulted in a functional gain from 30 to 58 dB with the VSB. Patients with a pure sensorineural hearing loss showed a functional gain of 23-30 dB. The VSB bone conduction threshold shift was analyzed for all studies conducted in the years between 2000 and 2009. In 11 of the 16 studies there was no significant (p=0.05) change found. In 5 studies, the pre- to post-surgical bone conduction threshold shift was less than 10 dB. None of these studies measured a threshold shift of more than 10 dB.The flexible attachment at either the long process of the incus with sensorineural hearing loss, with an conductive hearing loss at the round window or the use of Vibroplasty couplers at the oval window, head of the stapes or round window makes the VSB an extremely versatile instrument. If patients can't wear conventional hearing aids, had failed middle ear reconstructions or atresia the VSB presents, due to the significant hearing improvement in any type of hearing loss, an ideal solution.

  • Research Article
  • Cite Count Icon 71
  • 10.1002/lary.25670
Safety and effectiveness of the Vibrant Soundbridge in treating conductive and mixed hearing loss: A systematic review.
  • Oct 15, 2015
  • The Laryngoscope
  • Arne Ernst + 2 more

For many years, the therapeutic approach for conductive and/or mixed hearing loss has consisted of middle ear surgery with replacement of defect ossicles, and if possible the application of a hearing aid. Advances in technology have led to the introduction of electronmagnetic active implantable devices such as the Vibrant Soundbridge (VSB). With its various coupling techniques for different pathophysiological situations in the middle ear, the VSB offers greater improvement in the hearing performance of affected persons. PubMed, OvidSP (MEDLINE), EMBASE (DIMDI), the National Institue for Health research (NIHR) Centre for Reviews and Dissemination (including the National Health Service Economic Evaluation Database, Database of Abstracts of Reviews of Effects, and Health Technology Assessment), and the Cochrane Library were searched to identify articles published between January 2006 and April 2014 that evaluated the safety and effectiveness of the VSB in comparison to no intervention, bone conduction hearing implants (BCHI), and middle ear surgery plus hearing aids for adults and children with conductive or mixed hearing loss. Study selection and data extraction was carried out by multiple reviewers. Study quality was assessed using the Oxford Centre for Evidence-Based Medicine levels of evidence (2011); and a checklist available from the Evidence Analysis Library, Academy of Nutrition and Diabetics. Thirty-six publications were identified: 19 on VSB outcomes in 294 individuals, 13 on BCHI outcomes in 666 individuals, and four on middle ear surgery plus hearing aid outcomes in 43 individuals. Two systematic reviews were also identified. Heterogeneous outcome measures made it difficult to summarize data. In general, the VSB proved to be safe and effective when compared to no intervention and BCHI, and provided more and consistent hearing gain compared to middle ear surgery plus conventional hearing aids. As demonstrated in the literature, the VSB as an active device offers an effective alternative for patients with various middle ear pathologies, particularly with mixed hearing loss and failed previous tympanoplasties when classical ossiculoplasty could not provide enough functional gain. This new strategy in hearing rehabilitation has led to an improved quality of hearing and life. Laryngoscope, 126:1451-1457, 2016.

  • Research Article
  • Cite Count Icon 29
  • 10.1007/s00405-008-0862-y
Prospective radiological study concerning a series of patients suffering from conductive or mixed hearing loss due to superior semicircular canal dehiscence
  • Nov 12, 2008
  • European Archives of Oto-Rhino-Laryngology
  • Christian Martin + 5 more

The aim of this study is to appreciate the incidence of patients with isolated conductive hearing loss with normal drum due to superior semicircular canal dehiscence (SCD). It is a prospective radiological study. Two hundred and seventy-two patients with a normal drum suffering from isolated unilateral or bilateral conductive or mixed hearing loss were included in a prospective radiological study. A high resolution computerized tomography (HRCT) was performed in all the patients. Those who were found to have a unilateral or bilateral SCD underwent further etiological, clinical, audiologic evaluation. Ten patients with conductive or mixed hearing loss were found to have a unilateral or bilateral SCD. The disease was bilateral in five cases, and most often associated with a dehiscence of the tegmen tympani on both sides, supporting the theory of the congenital nature of the disease. There was no clear correlation between symptoms and the size of the SCD. Because patients were not suffering from incapacitating vestibular symptoms, they were not operated for surgical occlusion of the SCD, and were referred to a hearing aid specialist to improve hearing. Conductive or mixed hearing loss due to SCD is relatively frequent, justifying in our opinion that a systematic HRCT be carried out before surgery of any patient with conductive hearing loss.

Save Icon
Up Arrow
Open/Close
Notes

Save Important notes in documents

Highlight text to save as a note, or write notes directly

You can also access these Documents in Paperpal, our AI writing tool

Powered by our AI Writing Assistant