Abstract

The accurate description of the interfacial heat transfer coefficient is of great significance for the accurate measurement of the temperature field in the process of casting cooling. In this paper, the solidification process of metallic tin in refractory mould was studied by physical simulation experiment, and the on-site temperature measurement of the mold structure was carried out. According to the temperature record, the numerical simulation method is used to realize the fitting of the calculated temperature and the measured temperature. The reversible method was used to calculate the interfacial heat transfer coefficient between the casting and the mould, and then the evolution of the internal temperature field of the casting during the cooling process was determined. The results show that the melt has a large shrinkage during the cooling process, and the interface heat transfer coefficient can reach 300 W·m-2·K-1, which provides a mathematical model for the annealing process of fused-cast refractories.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.