Abstract

The paper deals with a series of tests conducted on a PV‐DC pump in Viterbo (42°24′ North, 12°06′ East). The tests lasted from January 2003 up to November 2004 and involved measurements of solar radiation, on both a horizontal surface and the tilted module surface, flow rates, volumes, and total dynamic heads. In total, up to 3000 data were collected every day whose analysis allowed us to find empirical relationships among system efficiencies, solar radiations, and total dynamic heads. In the second part of the paper we develop a simple method that allows both the assessment of performances of the whole system when installed in a different site from that in which the tests were performed and the optimal inclination angle of the panel to be determined in relation to annual or seasonal use (see irrigation).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.