Abstract
In this paper, the photoviscoelasticity method of viscoelastic stress analysis has been discussed in detail. It is shown that in order to avoid the effects of shrinkage and aging in the test specimens, it is suggested that the specimens should be tempered for three days at a temperature of 60°C before starting the experiments, and the temperature filtering arrangement is recommended in the experimental setups to keep the temperature absolutely constant. Besides the axi-symmetrical time-dependent stress state, the determination of the principle axes of the refraction tensor experimentally remains and unsufficiently solved problem. To avoid dynamic effect in the step wise loading, the time of measurement in every step should be limited in about one secend.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.