Abstract
A computer program, PHOTON, has been developed to calculate radiation levels associated with a general synchrotron beamline arrangement. PHOTON calculates the transmitted and scattered spectra as the synchrotron beam passes through sequential filters. The Compton component of this scattered radiation can then be passed through a series of materials composing a shielding wall. This radiation can then be used to calculate a dose in a medium outside of the shielding wall. Program input is such that the sequence of operations is easily followed and modified for any beamline configuration. Measurements have been performed by Braüer on existing NSLS beamlines in various geometries. Good agreement between calculated and measured dose values was found in all cases. This agreement implies that results obtained for shielding of sources containing a wide range of energies, such as that of the NSLS High Field Superconducting Wiggler, are correct.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.