Abstract

In this study, the authors found that treating blood with 1M HCl and 2% (w/v) 5-sulfosalicylic acid (SSA) in 1% (v/v) hydrogen peroxide mixture can produce photoluminescence of blood. SSA was added as a blood fixer. The photoluminescence was induced by irradiation of a forensic light source at 505nm, which was detected using a 550nm barrier filter. In this experiment, various level of acid and hydrogen peroxide were tested to find the optimal formulation of reagents, spot tests were conducted with diluted blood to test the sensitivity of this reagent, and impressions in blood left on porous/nonporous surfaces were enhanced. The sensitivity of this solution was slightly lower than Bluestar and was similar to leucocrystal violet or leucomalachite green on both porous/non-porous surfaces. The photoluminescence of blood treated with this reagent has been observed over 2months. Using this reagent, it was possible to observe fingermarks or footwear impressions in blood on a black porous/non-porous surface. Through this, it was found that using this reagent could enhance bloodstains regardless of the porosity or color of the surface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.