Abstract

A nonintrusive low-cost sensor based on silicon photodiode detectors has been designed to analyze the formation and behavior of excited CH(*) and C(2)(*) radicals in the combustion process by sensing the spectral emission of hydrocarbon flames. The sensor was validated by performing two sets of experiments for both nonconfined and confined flames. For a nonconfined oil flame, the sensor responses for the axial intensity were highly correlated with the measurements obtained with a radiometer. For confined gas flames the ratio between the signal corresponding to C(2)(*) and CH(*) was successfully correlated with the CO pollutant emissions and the combustion efficiency. These results give additional insight on how to prevent an incomplete combustion using spectral information. The fast response, the nonintrusive character, and the instantaneous measurement of the needed spectral information makes the proposed optical sensor a key element in the development of advanced control strategies for combustion processes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.