Abstract

The over-all velocity constants, kc' and lc' (in mm−1 x sec.−1), for the combination of O2 and CO, respectively, with reduced hemoglobin in 1:80 human red cell suspensions at 37°C have been measured in a Hartridge-Roughton continuous flow apparatus. Relative pigment concentration in the flowing cell suspension was estimated from the difference in light transmission at two different colors in order to reduce the influence of light scattering. The average value of kc' was 92; that for lc' was 79. Values for corresponding velocity constants for the uptake of O2 and CO by a membrane free layer of concentrated hemoglobin solution, comparable in dimensions to the erythrocyte, have been calculated from previously reported values for the rates of reaction and diffusion in hemoglobin solutions, and are, respectively, 3.6 and 2.3 times greater than kc' and lc'. We assume that this difference reflects the additional resistance to gas diffusion into the erythrocyte imposed by the cell membrane, and on this basis we have calculated values for the ratio of the permeability of the red cell membrane to the permeability of the red cell interior (λ). For human red cells at 37°C, the value of λ is about 1.5, both for O2 and for CO penetration. Submitted on February 15, 1957

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.