Abstract

To the editor: Fluorescence resonance energy transfer (FRET) efficiency between variants of fluorescent protein can be determined by photobleaching the acceptor molecule1. After complete acceptor bleaching, FRET efficiency equals the dequenched donor fluorescence divided by the total donor fluorescence. Recently, Valentin et al.2 reported that photobleaching of yellow fluorescent protein (YFP), Citrine and Venus (commonly used acceptor fluorescent protein tags) produced a species with an emission peak similar to that of cyan fluorescent protein (CFP), a widely-used donor fluorescent protein. This result predicts that FRET efficiency determined by acceptor photobleaching will be overestimated. As this prediction potentially impacts the accuracy of numerous existing studies and raises concerns about the validity of the photobleaching method, we examined the effects of acceptor fluorescent protein photobleaching using several imaging modalities commonly used in FRET experiments. We imaged HeLa cells coexpressing Venus and nuclear-localized CFP one day after transfection (Fig. 1a; Supplementary Methods online). Prolonged illumination through a YFP filter set (excitation: 500 ± 10 nm, emitter: 540 ± 15 nm, dichroic: 520LP) decreased the intensity of Venus fluorescence (YFP filter set) evenly throughout the cell. Conversely, the pattern and intensity of fluorescence detected through a CFP filter (excitation: 436 ± 10 nm, emitter: 480 ± 20 nm, dichroic: 455LP) remained unchanged. Additionally, fixation of cells expressing YFP or Venus with paraformaldehyde followed by photobleaching (50% decrease in YFP channel intensity) did not produce an increase in CFP channel fluorescence intensity (Supplementary Fig. 1 online). We obtained similar results (Supplementary Fig. 1) using CFP excitation (excitation: 406 ± 7.5 nm) similar to that used by Valentin et al.2. We determined the emission spectra of either Venus or YFP before and after photobleaching (514 nm argon ion laser) of fixed HeLa cells expressing these proteins. Photobleaching of Venus or YFP (> 50%) did not alter the shape of the emission spectra acquired with an LSM510 confocal microscope using two-photon excitation between 750 and 940 nm (Fig. 1b, and Supplementary Figs. 1 and 2 online). In particular, we observed no detectable increase in fluorescence intensity from 420–500 nm. This finding is in marked contrast to the result of Valentin et al.2. Our results demonstrate that photobleaching of YFP or Venus, under the conditions stated, does not produce CFP-like fluorescence, and thus FRET efficiency determination using acceptor photobleaching need not be encumbered by the reported phenomenon2. It is unclear why our results deviate from those of Valentin et al.2 as experimental conditions were similar (but not identical).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.