Abstract

Currently the detection of l-phenylalanine is quite important in clinicians, which can be applied as a simple quantitative method to diagnose phenylketonuria, a common inherited disorder of amino acid metabolism. In this work, a novel chiral fluorescence hybrid probe [email protected](D-cam) [CDs = Carbon-dot; D-cam = (1R, 3S)-(+)-Camphoric acid] can be successfully prepared through the encapsulation of the ultra-small carbon dots into the chiral Eu(D-cam) coordination framework to prepare the hybrid luminescent composites. The as-prepared fluorescent probe possesses good optical properties and solvent-stability, which has the potential to serve as a chemical sensor. The [email protected](D-cam) fluorescent probe behaves good liner response to l-phenylalanine (L-phe) ranging from 3.3 to 27.532 mg/L and the detection limit is 0.00703 mg/L (S/N = 3). The current detection method can be successfully developed into the real sample discrimination of l-phenylalanine in urine.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.