Abstract

Phosphorus removal by biological aerated filter(BAF) is ineffective, its effluent TP is much more than 0.5mg/L, so chemically enhanced phosphorus removal is neccessary. To solve this problem, domestic wastewater through BAF by adding metal salts in the aerobic tank was studied. The ferric chloride and aluminum chloride were chosen as the metal salts. The results showed that: the removal rate of TP rose with the Me/P (Me=Fe, Al)mass ratio increased, the influence on other performance of BAF by chemically enhanced synchronously was not severe, with TP in the effluent below the standard of 0.5mg/L; to ensure the concentration of effluent TP was less than 0.5mg/L, the optimum mass ratios of dosing were Fe/P=3, Al/P=2.5; proper aeration intensity could maintain the proper micro-flocculation state in BAF, which was helpful to TP removal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.