Abstract

The quantification of PC hydroperoxide (PCOOH) in human plasma was studied by HPLC with chemiluminescence detection (HPLC-CL). We identified for the first time the monohydroperoxide of 1-palmitoyl-2-linoleoyl-PC hydroperoxide (PC 16:0/18:2-OOH) in plasma by LC-MS and HPLC-CL. The standard compound, PC 16:0/18:2-OOH (synthetic PCOOH), as well as PCOOH from egg yolk, was used. Comparison of the PCOOH concentration in each participant's plasma as determined by use of a Finepak SIL NH2 column with 2-propanol/methanol/water as the mobile phase (system A, the conventional method) gave a higher concentration than did an LC-18-DB column with methanol containing 0.01% triethylamine (system B). The mean PCOOH concentration for the 43 healthy volunteers was 55.1+/-30.4 pmol/mL (mean+/-SD) for system A and 16.3+/-9.9 pmol/mL for system B. Moreover, the main peak of the plasma extract appeared at a different time from that of synthetic PCOOH or egg yolk PCOOH in system A, whereas in system B plasma sample retention time practically corresponded to that of standard PCOOH. These findings confirm that the PCOOH plasma concentration is not so high as previously reported.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.